Midea MAD50C1AWS (check full data plate); do not confuse it with a similar MAD50 pump-equipped suffix. The cited document distinguishes pump and no-pump protection codes.
Find the cause and fix it
Ice forms during low room temperatures
- Stop cooling, let coil thaw naturally, move to the manual's approved operating temperature range and keep doors/windows closed while the room recovers.
Airflow over evaporator is blocked
- Unplug, remove the filter, wash/dry it as specified, clear blocked inlet and outlet space, then reinstall before running.
Ice rapidly reforms in a warm room with filter clear
- Stop continuous operation and investigate evaporator temperature sensor, refrigeration charge and fan by trained service.
- Do not scrape the coil or use a heater to force defrost.
Model source and method basis
Reference: Read corresponding manufacturer/manual source ↗
The fault definitions, named controls and any published specifications follow the linked documentation. Ordered isolation tests are conservative explanatory procedures, not a claim that all checks are verbatim factory service instructions. If the stated manual does not establish a measurement or part compatibility, this guide deliberately does not invent it.