Home / Dehumidifiers / Midea MAD50C1AWS
DEHUMIDIFIERS / TROUBLESHOOTING HUB

Midea MAD50C1AWS: Fault Codes, Common Problems and Fixes

Search the verified code definitions where available, or choose your actual symptom. Read the full repair guide before purchasing replacement parts.

First, identify the correct variant

MAD50C1AWS non-pump model; do not apply MAD50P1AWS pump-only instructions.

CODE REFERENCE

Fault codes and applicability

The shared MAD-series manual also mentions Eb/E3 on certain pump-equipped versions. Do not apply pump-only alerts to the non-pump MAD50C1AWS without confirming its feature set.

CodeManufacturer-defined meaning or evidence limit
ASHumidity sensor fault
ESEvaporator temperature sensor fault
P2Bucket full / not correctly seated; non-pump model
ECRefrigerant leak detection
PROBLEM SOLVER

9 repair questions for this model

Each individual guide links a specific symptom or fault code to checks, expected results, possible fixes, and a post-repair test.

Why Does My Midea MAD50C1AWS Keep Showing P2?

On the non-pump MAD50C1AWS, P2 means the water bucket is full or is not seated correctly. The pump-model wording does not apply to this model.

How Do I Clear Error AS on a Midea MAD50C1AWS?

AS is a room-humidity sensor error on the applicable MAD50C1AWS manual. The manufacturer’s user-level remedy is a power cycle, not an internal sensor replacement procedure.

What Does ES Mean on My Midea MAD50C1AWS Dehumidifier?

ES refers to the evaporator tube temperature-sensor circuit in the applicable Midea manual. It does not, by itself, prove a refrigerant leak.

Why Is My Midea MAD50C1AWS Showing EC?

EC is the refrigerant-leak detection warning in the applicable Midea fault table. It is not a suggestion to refill the system yourself.

Why Won’t My Midea MAD50C1AWS Dehumidifier Turn On?

Before assuming a failed compressor, check the outlet, full-bucket shutoff and humidity setting. The manual lists all three as ordinary reasons the unit will not run.

Why Is My Midea MAD50C1AWS Running but Not Collecting Water?

If the fan runs but little water collects, check the set humidity, blocked airflow and room temperature before diagnosing the refrigeration system.

Why Is My Midea MAD50C1AWS Dehumidifier Making a Loud Noise?

The Midea troubleshooting table starts with the washable filter and machine leveling, not immediate replacement of the fan or compressor.

Why Is My Midea MAD50C1AWS Leaking Water onto the Floor?

Water on the floor often comes from the rear drain plug or a loose gravity-drain hose. Verify which collection mode is being used before disassembling the cabinet.

Why Are the Coils on My Midea MAD50C1AWS Freezing Up?

The model has an automatic defrost cycle. Some frost can be expected during defrost operation; persistent thick ice with poor drying needs airflow and room-temperature checks.