Safety first: Turn off and disconnect power before accessing the fan, pump, wiring or panels; shut off water for hose or inlet work. Refrigerant/compressor service requires certified refrigeration personnel.
Confirm exact model and variant
VEVOR CIM-360T with the E1/E2/E3/E5 table in the corresponding manual. Confirm the exact controller and machine-label revision before applying any code or service instruction.
Version check: Match the ice-maker controller revision before assuming an E-code has the same meaning across batches.
DIAGNOSE THE CAUSE · APPLY THE FIX · CONFIRM THE RESULT
Find the cause and fix it
Jump to your symptom: 01 · Display E1 with ice process stopping02 · Code persists with stable ambient conditions and intact lead
01
Display E1 with ice process stopping
HOW TO CHECK & CORRECT THIS CAUSE
- First match E1 to the exact CIM-360T controller manual.
- The previously identified version uses E1 for temperature probe open circuit.
- Power off and inspect only accessible unplugged temperature-sensor plug/harness for disconnected or cut wire.
How to tell it is fixed: E1 clears if a loose connector is corrected.
02
Code persists with stable ambient conditions and intact lead
HOW TO CHECK & CORRECT THIS CAUSE
- Replace model-revision-correct temperature sensor after qualified resistance/continuity diagnosis.
- Don't fit a random NTC based on physical size.
How to tell it is fixed: E1 absent through complete ice-making and harvest cycles.
Model source and method basis
Reference: Read corresponding manufacturer/manual source ↗
The fault definitions, named controls and any published specifications follow the linked documentation. Ordered isolation tests are conservative explanatory procedures, not a claim that all checks are verbatim factory service instructions. If the stated manual does not establish a measurement or part compatibility, this guide deliberately does not invent it.