Safety first: Turn off and disconnect power before accessing the fan, pump, wiring or panels; shut off water for hose or inlet work. Refrigerant/compressor service requires certified refrigeration personnel.
Confirm exact model and variant
VEVOR CIM-360T with the E1/E2/E3/E5 table in the corresponding manual. Confirm the exact controller and machine-label revision before applying any code or service instruction.
Version check: Match the ice-maker controller revision before assuming an E-code has the same meaning across batches.
DIAGNOSE THE CAUSE · APPLY THE FIX · CONFIRM THE RESULT
Find the cause and fix it
Jump to your symptom: 01 · E2 appears immediately after self-check02 · Sensor wiring is intact but E2 remains
01
E2 appears immediately after self-check
HOW TO CHECK & CORRECT THIS CAUSE
- For the specific researched controller E2 relates to a temperature-probe short circuit.
- Unplug and inspect wet/pinched sensor wiring, dry or replace damaged lead without defeating sensor circuit.
How to tell it is fixed: Normal sensor reading resumes and E2 clears.
02
Sensor wiring is intact but E2 remains
HOW TO CHECK & CORRECT THIS CAUSE
- Qualified technician measures and replaces matched temperature sensor/controller input as warranted by exact service chart.
How to tell it is fixed: Ice maker cycles without repeated E2.
Model source and method basis
Reference: Read corresponding manufacturer/manual source ↗
The fault definitions, named controls and any published specifications follow the linked documentation. Ordered isolation tests are conservative explanatory procedures, not a claim that all checks are verbatim factory service instructions. If the stated manual does not establish a measurement or part compatibility, this guide deliberately does not invent it.