Home / Genmitsu 3018-PROVer V2 / Troubleshooting
DESKTOP CNC ROUTERS / MODEL-SPECIFIC REPAIR

Why Won’t My Genmitsu 3018-PROVer V2 Move After an Emergency Stop?

Quick answer: Remove tool from workpiece, twist mushroom E-stop in the direction marked on switch until it pops out.

Safety first: Use the E-stop, unplug spindle/machine power before touching tools, switches or couplers, and keep hands out of axis travel. Never bypass a hard-limit switch to run a cutting job; do not loosen a powered spindle or jog an axis into its physical end.
Model and version covered

Genmitsu 3018-PROVer V2 with GRBL-compatible controller. Check board marking and firmware before applying GRBL commands; the older 3018-PROVer and V2 Lite do not necessarily have identical connectors.

Version check: Confirm controller, GRBL firmware and actual limit/probe connections before changing parameters or running automated motion.
DIAGNOSE THE CAUSE · APPLY THE FIX · CONFIRM THE RESULT

Find the cause and fix it

01

Candle cannot move machine after E-stop

HOW TO CHECK & CORRECT THIS CAUSE
  1. Remove tool from workpiece, twist mushroom E-stop in the direction marked on switch until it pops out.
  2. Ensure machine mains/24V supply is restored, reconnect Candle, then clear controller alarm using documented command after confirming safe position.
How to tell it is fixed: Short air-cut jog responds normally.
02

E-stop physically released but machine still unresponsive

HOW TO CHECK & CORRECT THIS CAUSE
  1. With power removed, inspect E-STOP cable and connector to controller board, replace faulty contact/switch only with matching safety-rated component.
How to tell it is fixed: E-stop stops the spindle/motion reliably, then releases normally after reset.
03

E-stop circuit has been bypassed or behavior uncertain

HOW TO CHECK & CORRECT THIS CAUSE
  1. Do not operate CNC without functional emergency-stop circuit.
  2. Have it rewired by competent service before use.
How to tell it is fixed: Pressing E-stop stops motion every test.